{"title":"Split Bolt Connectors | Copper Alloy | 16 AWG - 500 MCM | Conversions Tech","description":"\u003cp\u003eCopper alloy split bolt connectors for splicing, tapping, and grounding — solid, stranded, and rebar combinations from 16 AWG through 500 kcmil. UL\/ANSI certified, 600 V, 90°C rated. Same-day shipping.\u003c\/p\u003e","products":[{"product_id":"cervit-post-2","title":"Post mechanical split bolt #2","description":"\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e \u003cmeta name=\"description\" content=\"Discover the Cervit Post #2, a high-quality grounding electrode made of copper alloy, designed for robust electrical systems. Reliable, durable, and efficient for grounding applications.\"\u003e Cervit Post #2 - Reliable Grounding Electrode for Electrical Systems\n\u003ch1\u003eCervit Post #2: Grounding Electrode for Electrical Systems\u003c\/h1\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eCervit Post #2\u003c\/strong\u003e, a cornerstone of reliability and durability in the realm of grounding electrodes. Crafted meticulously from high-strength copper alloy, this post is equipped with a threaded metal rod ensuring a low-impedance pathway to earth, vital during short circuits or other electrical discrepancies.\u003c\/p\u003e\n\u003ch2\u003eFeatures:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobust grounding electrode for electrical system stability\u003c\/li\u003e\n\u003cli\u003eConstructed from high-quality copper alloy\u003c\/li\u003e\n\u003cli\u003eThreaded metal rod for dependable low-impedance grounding\u003c\/li\u003e\n\u003cli\u003e#2 gauge metal rod, guaranteeing safe current flow without system compromise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe gauge prominence of this Cervit post ensures it can manage substantial currents, ensuring system safety. Consequently, it emerges as the top pick for high-capacity grounding scenarios.\u003c\/p\u003e\n\u003ch3\u003eBenefits:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUser-friendly installation process\u003c\/li\u003e\n\u003cli\u003eHigh compatibility across diverse electrical setups\u003c\/li\u003e\n\u003cli\u003eResilience against corrosion, moisture, and wear\u003c\/li\u003e\n\u003cli\u003eExtensive lifespan, even in demanding conditions\u003c\/li\u003e\n\u003cli\u003eCost-efficient grounding solution for electrical experts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Dimensions:\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eA\/F\u003c\/th\u003e\n\u003cth\u003eTotal Length\u003c\/th\u003e\n\u003cth\u003eThread A\u003c\/th\u003e\n\u003cth\u003eThread B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.88\u003c\/td\u003e\n\u003ctd\u003e3.15\u003c\/td\u003e\n\u003ctd\u003e1\/2\" X 13 UNC\u003c\/td\u003e\n\u003ctd\u003e7\/8\" X 14 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWire Compatibility:\u003c\/h3\u003e\n\u003cp\u003eMIN: 2 AWG (STR) | MAX: 2\/0 AWG (STR)\u003c\/p\u003e\n\u003cp\u003eIn essence, the Cervit Post #2 stands as a paragon in the realm of grounding electrodes, merging quality, efficiency, and durability. Its vast compatibility, combined with its resilience against environmental challenges, positions it as the top choice for electrical professionals.\u003c\/p\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":41083349139508,"sku":"6400-0018","price":30.01,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/products\/post-mechanical-split-bolt-2-1157099125.png?v=1745299578"},{"product_id":"split-bolt-connector-6-sol-10","title":"Split Bolt Connector 6 Awg (Max) - 10 Awg (Max)","description":"\u003ch1\u003eSplit Bolt Connector – 6 AWG (Max) to 10 AWG (Max) | UL\/ANSI Certified Splicing\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eConversions Tech Split Bolt Connector (6 AWG to 10 AWG)\u003c\/strong\u003e is a \u003cem\u003eUL\/ANSI-certified mechanical connector\u003c\/em\u003e crafted for safe and dependable splicing of solid conductors. Built with \u003cstrong\u003ehigh-conductivity copper alloy\u003c\/strong\u003e and protected by a \u003cstrong\u003etin-plated coating\u003c\/strong\u003e, this connector provides a robust and low-resistance splice for \u003cstrong\u003eresidential, commercial, and industrial electrical systems\u003c\/strong\u003e. Its precise engineering and durable materials make it ideal for applications demanding long-lasting electrical and mechanical integrity.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Range:\u003c\/strong\u003e Securely supports 6 AWG (max) to 10 AWG (max) solid conductors; taps to 16 SOL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Made from premium copper alloy for excellent conductivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e Tin plating enhances resistance to oxidation in demanding environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Tolerance:\u003c\/strong\u003e Rated for continuous operation up to 90 °C (194 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Fully UL Listed and ANSI compliant for safety and code adherence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Installation:\u003c\/strong\u003e Wrench-tight design allows fast and reliable field assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWire Size\u003c\/th\u003e\n\u003ctd\u003e6 AWG (max) – 10 AWG (max); tap to 16 SOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody Material\u003c\/th\u003e\n\u003ctd\u003eCopper alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eTin-plated for enhanced corrosion resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Rating\u003c\/th\u003e\n\u003ctd\u003eUp to 90 °C (194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Applications\u003c\/th\u003e\n\u003ctd\u003eStandard residential and commercial electrical systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards Met\u003c\/th\u003e\n\u003ctd\u003eUL Listed, ANSI compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Wiring:\u003c\/strong\u003e Reliable splicing for branch circuits and grounding conductor repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Power Systems:\u003c\/strong\u003e Trusted connector for junction boxes, panelboards, and structured cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Installations:\u003c\/strong\u003e Maintains secure, long-term connections under demanding electrical loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance \u0026amp; Repair:\u003c\/strong\u003e Perfect for retrofitting, upgrades, and on-site circuit modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh Environments:\u003c\/strong\u003e Effectively resists moisture, heat, and chemical exposure—when insulated per NEC 110.14(B).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTrust the \u003cstrong\u003eConversions Tech 6 AWG – 10 AWG Split Bolt Connector\u003c\/strong\u003e for secure, code-compliant electrical splicing. Engineered for durability and performance, it stands up to the demands of professional residential, commercial, and industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/split-bolts\"\u003e← Browse all Split Bolt Connector sizes\u003c\/a\u003e\u003c\/p\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":44665250381876,"sku":"610-00610","price":1.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/split-bolt-connector-6-awg-max-10-awg-max-1157096858.jpg?v=1745382007"},{"product_id":"split-bolt-connector-4-sol-8-sol","title":"Split Bolt Connector 4 Awg (Max) - 8 Awg (Max)","description":"\u003c!--\nSEO Meta Title:\nConversions Tech Copper Split Bolt Connector | 4 SOL to 8 SOL Wire Range | Heavy-Duty Splice \u0026 Tap\n\nSEO Meta Description:\nShop Conversions Tech copper split bolt connectors for secure splicing and tapping. Fits 4 SOL to 8 SOL conductors, corrosion-resistant finish options, 90°C rated. Includes specs, applications, and 10+ FAQs.\n--\u003e\n\u003csection class=\"ct-product\"\u003e\n\u003ch1\u003eConversions Tech Copper Split Bolt Connector – Heavy-Duty Wire Splice \u0026amp; Tap (4 SOL to 8 SOL)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eConversions Tech Split Bolt Connector\u003c\/strong\u003e is a rugged, high-conductivity connector designed for \u003cstrong\u003esplicing\u003c\/strong\u003e and \u003cstrong\u003etapping\u003c\/strong\u003e copper conductors in power distribution, grounding, and general electrical installations. The split-bolt design applies strong, even clamping force to create a dependable electrical bond, while the heavy-duty body resists loosening in vibration-prone environments.\u003c\/p\u003e\n\u003cp\u003eBuilt for electricians, contractors, and maintenance teams, this connector is commonly used for field repairs, service upgrades, and permanent connections where a reliable mechanical grip and low-resistance electrical path are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch terms:\u003c\/strong\u003e split bolt connector, copper split bolt, wire splice connector, wire tap connector, copper splice, grounding split bolt, electrical split bolt, 4 SOL to 8 SOL connector, heavy duty split bolt\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose a Conversions Tech Split Bolt Connector\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure splicing \u0026amp; tapping:\u003c\/strong\u003e Ideal for joining conductors inline or tapping a branch conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh conductivity:\u003c\/strong\u003e Copper construction supports efficient current transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong mechanical grip:\u003c\/strong\u003e Split-bolt clamping force helps resist loosening over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion resistance options:\u003c\/strong\u003e Tin-plated or nickel-plated finishes available for added protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-friendly installation:\u003c\/strong\u003e Simple, tool-driven install for fast work in panels or junction areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e4 SOL to 8 SOL conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eCopper (high conductivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eTin-plated or nickel-plated (corrosion resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eUp to 90°C (194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eSuitable for standard electrical systems (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eCompliant with applicable UL and ANSI requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSplicing copper conductors in residential and commercial electrical systems\u003c\/li\u003e\n\u003cli\u003eTapping a branch conductor from a main run\u003c\/li\u003e\n\u003cli\u003eGrounding and bonding connections (where permitted by your design\/spec)\u003c\/li\u003e\n\u003cli\u003eMaintenance repairs and electrical retrofits\u003c\/li\u003e\n\u003cli\u003eOutdoor and harsh-environment installs when paired with corrosion protection measures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong mechanical + electrical bond\u003c\/strong\u003e for long-term reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy installation\u003c\/strong\u003e with standard hand tools\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant finish options\u003c\/strong\u003e for longer service life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile wire range\u003c\/strong\u003e for common conductor sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContractor-grade build\u003c\/strong\u003e for demanding jobsite conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVerify conductor type and size are within the listed wire range before installation.\u003c\/li\u003e\n\u003cli\u003eClean conductors and ensure proper seating to maximize contact area.\u003c\/li\u003e\n\u003cli\u003eTighten hardware evenly to achieve a secure connection (do not overtighten).\u003c\/li\u003e\n\u003cli\u003eFor outdoor or corrosive environments, use appropriate sealing and protective measures per job requirements.\u003c\/li\u003e\n\u003cli\u003eAlways follow your local electrical code and project specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e1) What is a split bolt connector used for?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSplit bolt connectors are used to \u003cstrong\u003esplice\u003c\/strong\u003e conductors inline or \u003cstrong\u003etap\u003c\/strong\u003e a branch conductor from a main run.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e2) What wire sizes does this connector fit?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis connector is designed for \u003cstrong\u003e4 SOL to 8 SOL\u003c\/strong\u003e conductors.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e3) Is this connector copper or aluminum?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis version is \u003cstrong\u003ecopper\u003c\/strong\u003e for high conductivity. (If you need aluminum or AL\/CU options, we can help cross-reference.)\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e4) What’s the difference between tin-plated and nickel-plated?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eBoth finishes improve corrosion resistance. Tin plating is common for general electrical use; nickel plating may be preferred for certain harsh or chemical environments.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e5) Can I use this for outdoor installations?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, but outdoor reliability depends on the environment and protection method. Use corrosion-resistant finishes and appropriate sealing\/protective measures as required by your project.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e6) Does it work for grounding and bonding?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSplit bolt connectors are often used for grounding\/bonding where permitted by the design and code. Always confirm with your project spec and local electrical code.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e7) What temperature rating does it have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis connector is rated up to \u003cstrong\u003e90°C (194°F)\u003c\/strong\u003e in typical applications.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e8) Do I need special tools to install it?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo special tools are usually required—standard hand tools are typically sufficient. Ensure proper tightening and conductor seating.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e9) Will vibration loosen the connection?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eWhen installed properly, the split-bolt design provides strong clamping force and is commonly used in demanding environments. For high-vibration applications, follow best practices and inspection intervals.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e10) Can this connector be reused?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eIn many cases, split bolts can be removed and reinstalled, but reuse depends on condition, deformation, and your project standards. For critical installations, replacement is recommended.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e11) Is this connector insulated?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. Split bolt connectors are typically \u003cstrong\u003euninsulated\u003c\/strong\u003e. Proper insulation\/overwrap should be applied after installation if required.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e12) How do I choose the right split bolt size?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSelect the connector based on conductor sizes being joined (main + tap). If you share the two conductor sizes, we can recommend the correct option.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003chr\u003e\n\u003ch2\u003eDocumentation\u003c\/h2\u003e\n\u003cp\u003eNeed drawings or a spec sheet for submittals? Contact Conversions Tech and we’ll provide the latest documentation for your exact configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp style=\"font-size: 0.9em; color: #6b7280;\"\u003e© Conversions Tech. All rights reserved.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":44665326075956,"sku":"610-0048","price":2.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/split-bolt-connector-4-awg-max-8-awg-max-1157096864.jpg?v=1745382019"},{"product_id":"split-bolt-connector-500-mcm-max-250-mcm-max","title":"Split Bolt Connector 500 MCM (Max) - 250 MCM (Max)","description":"\u003c!--\nSEO Meta Title:\nConversions Tech 500 MCM – 250 MCM Copper Split Bolt Connector | Heavy-Duty Electrical Splicing\n\nSEO Meta Description:\nShop Conversions Tech 500 MCM to 250 MCM split bolt connectors for heavy-duty copper splicing. UL Listed, ANSI compliant, 90°C rated, corrosion-resistant finishes. Full specs, applications, and 10+ FAQs.\n--\u003e\n\u003csection class=\"ct-product\"\u003e\n\u003ch1\u003eConversions Tech Copper Split Bolt Connector – 500 MCM to 250 MCM Heavy-Duty Splicing\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eConversions Tech 500 MCM – 250 MCM Split Bolt Connector\u003c\/strong\u003e is a \u003cstrong\u003eheavy-duty mechanical connector\u003c\/strong\u003e engineered for secure splicing, joining, and terminating large copper conductors in demanding electrical systems. Designed to meet \u003cstrong\u003eUL Listed\u003c\/strong\u003e and \u003cstrong\u003eANSI-compliant\u003c\/strong\u003e requirements, this connector delivers dependable mechanical strength and low-resistance electrical performance for high-load applications.\u003c\/p\u003e\n\u003cp\u003eManufactured from a \u003cstrong\u003ehigh-grade brass alloy\u003c\/strong\u003e with optional \u003cstrong\u003etin-plated or nickel-plated finishes\u003c\/strong\u003e, this split bolt provides excellent conductivity while resisting corrosion in harsh environments. Its wrench-tightened design ensures fast, consistent field installation for residential, commercial, and industrial power distribution systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch terms:\u003c\/strong\u003e 500 MCM split bolt, 250 MCM split bolt, copper split bolt connector, heavy duty split bolt, large conductor splice, service entrance connector, UL listed split bolt\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty conductor range:\u003c\/strong\u003e Accommodates copper conductors from \u003cstrong\u003e500 MCM down to 250 MCM\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-strength brass body:\u003c\/strong\u003e Provides durability and excellent electrical conductivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant finishes:\u003c\/strong\u003e Available in tin-plated or nickel-plated options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal endurance:\u003c\/strong\u003e Rated for continuous operation up to \u003cstrong\u003e90°C (194°F)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL \u0026amp; ANSI compliant:\u003c\/strong\u003e Meets applicable safety and performance standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-friendly installation:\u003c\/strong\u003e Wrench-tightened design enables fast, secure assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eConductor Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e500 MCM – 250 MCM (copper conductors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eHigh-grade brass alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eFinish Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eTin-plated or nickel-plated (corrosion resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e90 °C (194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eLow- and medium-voltage distribution systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eUL Listed, ANSI Compliant, NEC 110.14(B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential:\u003c\/strong\u003e Splicing large service entrance conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial:\u003c\/strong\u003e Multi-conductor connections in distribution panels and switchboards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial:\u003c\/strong\u003e High-load feeders, busbar terminations, and heavy-duty splicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance \u0026amp; Upgrades:\u003c\/strong\u003e Efficient repairs and system modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor \/ Underground:\u003c\/strong\u003e Suitable for harsh environments when properly insulated per NEC 110.14(B).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVerify conductor sizes fall within the listed 500 MCM to 250 MCM range.\u003c\/li\u003e\n\u003cli\u003eClean conductors prior to installation to maximize contact area.\u003c\/li\u003e\n\u003cli\u003eTighten hardware evenly using appropriate torque for the application.\u003c\/li\u003e\n\u003cli\u003eApply insulation or protective covering after installation as required by code.\u003c\/li\u003e\n\u003cli\u003eFollow all applicable NEC, local code, and project specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e1) What conductor sizes does this split bolt support?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis split bolt connector is designed for copper conductors ranging from \u003cstrong\u003e500 MCM down to 250 MCM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e2) What material is the connector made from?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe connector is manufactured from a \u003cstrong\u003ehigh-grade brass alloy\u003c\/strong\u003e for strength and conductivity.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e3) Is this connector UL Listed?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. This split bolt is \u003cstrong\u003eUL Listed\u003c\/strong\u003e and compliant with applicable ANSI standards.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e4) Can this be used for outdoor installations?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, when properly insulated and installed in accordance with \u003cstrong\u003eNEC 110.14(B)\u003c\/strong\u003e and local codes.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e5) What finish options are available?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eFinish options include \u003cstrong\u003etin-plated\u003c\/strong\u003e and \u003cstrong\u003enickel-plated\u003c\/strong\u003e versions for enhanced corrosion resistance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e6) What temperature rating does this connector have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis split bolt is rated for continuous operation up to \u003cstrong\u003e90°C (194°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e7) Is this connector suitable for service entrance conductors?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. It is commonly used for \u003cstrong\u003elarge service entrance splicing\u003c\/strong\u003e in residential and commercial systems.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e8) Do I need special tools to install it?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo specialized tools are required—standard hand tools are typically sufficient. Proper tightening is essential.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e9) Can this connector be reused?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eReuse may be possible depending on condition, but for critical or permanent installations, replacement is recommended.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e10) Is this connector insulated?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. Split bolt connectors are typically \u003cstrong\u003euninsulated\u003c\/strong\u003e and must be insulated after installation if required.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e11) Does it support grounding and bonding applications?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. This connector is often used for grounding and bonding where permitted by design and electrical code.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e12) How do I choose the correct split bolt size?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSelect the connector based on the largest and smallest conductors being joined. If you need help, Conversions Tech can assist with selection.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose Conversions Tech\u003c\/h2\u003e\n\u003cp\u003eConversions Tech split bolt connectors are trusted by electrical contractors, utilities, and OEMs for delivering \u003cstrong\u003ecode-compliant\u003c\/strong\u003e, \u003cstrong\u003edurable\u003c\/strong\u003e, and \u003cstrong\u003elong-lasting\u003c\/strong\u003e electrical connections across residential, commercial, and industrial installations.\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9em; color: #6b7280;\"\u003e© Conversions Tech. All rights reserved.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":44665470451764,"sku":"610-00500","price":20.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/split-bolt-connector-500-mcm-max-250-mcm-max-1157095942.jpg?v=1745384296"},{"product_id":"split-bolt-connector-2-str-6-sol","title":"Split Bolt Connector 2 Awg (Max) - 6 Awg (Max)","description":"\u003c!--\nSEO Meta Title:\nConversions Tech Split Bolt Connector | 2 STR to 6 SOL Copper Splicing | Heavy-Duty Electrical Connector\n\nSEO Meta Description:\nConversions Tech split bolt connector for splicing 2 STR to 6 SOL conductors. UL \u0026 ANSI compliant, corrosion-resistant finishes, 90°C rated. Includes specs, applications, and 10+ FAQs.\n--\u003e\n\u003csection class=\"ct-product\"\u003e\n\u003ch1\u003eConversions Tech Split Bolt Connector – 2 STR to 6 SOL Heavy-Duty Wire Splicing\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eConversions Tech Split Bolt Connector\u003c\/strong\u003e is a versatile, heavy-duty mechanical connector engineered for \u003cstrong\u003esecure splicing and joining of copper conductors\u003c\/strong\u003e ranging from \u003cstrong\u003e2 STR to 6 SOL\u003c\/strong\u003e. Designed for reliability and ease of installation, this connector delivers a strong mechanical grip and low-resistance electrical connection suitable for residential, commercial, and light industrial applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing a rugged split-bolt design, this connector applies uniform clamping pressure across conductors, ensuring long-term performance even in vibration-prone or demanding environments. Available with \u003cstrong\u003etin-plated or nickel-plated finishes\u003c\/strong\u003e, it offers enhanced corrosion resistance for indoor and outdoor installations when properly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch terms:\u003c\/strong\u003e split bolt connector, copper split bolt, 2 STR split bolt, 6 SOL split bolt, wire splice connector, electrical splice, grounding split bolt, UL listed split bolt\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide conductor range:\u003c\/strong\u003e Supports copper conductors from \u003cstrong\u003e2 STR to 6 SOL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure mechanical connection:\u003c\/strong\u003e Split-bolt design ensures strong, even clamping force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-conductivity construction:\u003c\/strong\u003e Copper body provides efficient current transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant finishes:\u003c\/strong\u003e Tin-plated or nickel-plated options available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90°C temperature rating:\u003c\/strong\u003e Suitable for demanding electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL \u0026amp; ANSI compliant:\u003c\/strong\u003e Meets recognized safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e2 STR to 6 SOL conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eCopper (high conductivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eFinish Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eTin-plated or nickel-plated for corrosion resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eUp to 90 °C (194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eSuitable for standard electrical systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eCompliant with UL and ANSI standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSplicing copper conductors in residential wiring systems\u003c\/li\u003e\n\u003cli\u003eConnecting multiple conductors in commercial electrical installations\u003c\/li\u003e\n\u003cli\u003eElectrical bonding and grounding applications (where permitted)\u003c\/li\u003e\n\u003cli\u003eRepairs and upgrades to existing wiring systems\u003c\/li\u003e\n\u003cli\u003eOutdoor and harsh-environment installations when properly insulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm conductor sizes fall within the 2 STR to 6 SOL range before installation.\u003c\/li\u003e\n\u003cli\u003eClean conductors thoroughly to maximize contact area.\u003c\/li\u003e\n\u003cli\u003eTighten split-bolt hardware evenly to ensure a secure connection.\u003c\/li\u003e\n\u003cli\u003eApply insulation or protective covering after installation as required by code.\u003c\/li\u003e\n\u003cli\u003eAlways follow NEC, local electrical codes, and project specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e1) What is a split bolt connector used for?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSplit bolt connectors are used to splice conductors inline or tap one conductor onto another.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e2) What wire sizes does this connector support?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis connector supports copper conductors from \u003cstrong\u003e2 STR to 6 SOL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e3) Is this connector copper or aluminum?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis version is copper. If aluminum or AL\/CU connectors are required, contact Conversions Tech for alternatives.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e4) What finish options are available?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eFinish options include \u003cstrong\u003etin-plated\u003c\/strong\u003e and \u003cstrong\u003enickel-plated\u003c\/strong\u003e for corrosion resistance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e5) Is this connector suitable for outdoor use?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, when properly insulated and protected according to code and environmental requirements.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e6) What temperature rating does it have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe connector is rated for continuous operation up to \u003cstrong\u003e90°C (194°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e7) Is this connector UL Listed?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, this split bolt connector is compliant with applicable \u003cstrong\u003eUL and ANSI standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e8) Do I need special tools to install it?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo specialized tools are required. Standard hand tools are typically sufficient for installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e9) Can this connector be reused?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eReuse may be possible depending on condition, but for critical or permanent installations, replacement is recommended.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e10) Is this connector insulated?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. Split bolt connectors are uninsulated and require insulation after installation if specified.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e11) Is this suitable for grounding and bonding?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, split bolt connectors are commonly used for grounding and bonding where allowed by design and code.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e12) How do I select the correct split bolt size?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSelect the connector based on the largest and smallest conductors being joined. Conversions Tech can assist with selection if needed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003chr\u003e\n\u003ch2\u003eDocumentation\u003c\/h2\u003e\n\u003cp\u003eDownload the full specification sheet and technical drawing for complete dimensional and compliance information: \u003cbr\u003e\u003cstrong\u003eSpecification Sheet\u003c\/strong\u003e | \u003cstrong\u003eTechnical Drawing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9em; color: #6b7280;\"\u003e© Conversions Tech. All rights reserved.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":44665512951860,"sku":"610-00261","price":4.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/split-bolt-connector-2-awg-max-6-awg-max-1157096866.jpg?v=1745401803"},{"product_id":"split-bolt-connector-350-mcm-4-0-sol","title":"Split Bolt Connector 350 MCM (Max) - 4\/0 Awg (Min)","description":"\u003c!--\nSEO Meta Title:\nConversions Tech Split Bolt Connector | 350 MCM to 4\/0 SOL | Heavy-Duty Brass Electrical Splicing\n\nSEO Meta Description:\nConversions Tech split bolt connector for copper conductors from 350 MCM to 4\/0 AWG solid. UL Listed, ANSI C119.4 \u0026 NEC compliant, 90°C rated, corrosion-resistant brass construction. Specs, applications, and 10+ FAQs.\n--\u003e\n\u003csection class=\"ct-product\"\u003e\n\u003ch1\u003eConversions Tech Split Bolt Connector – 350 MCM to 4\/0 SOL Heavy-Duty Brass Splicing\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eConversions Tech Split Bolt Connector\u003c\/strong\u003e is a high-performance electrical connector engineered for \u003cstrong\u003esecure splicing and termination of large-gauge copper conductors\u003c\/strong\u003e ranging from \u003cstrong\u003e350 MCM to 4\/0 AWG Solid (SOL)\u003c\/strong\u003e. Designed for demanding electrical environments, this connector delivers superior electrical conductivity, strong mechanical retention, and long-term corrosion resistance across industrial, commercial, and power distribution applications.\u003c\/p\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003ehigh-strength, high-conductivity brass (CuZn alloy)\u003c\/strong\u003e, this split bolt provides consistent clamping force and excellent resistance to deformation under load. Precision-machined threads and a robust bolt design ensure reliable electrical contact even in installations subject to vibration, thermal cycling, and high current loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch terms:\u003c\/strong\u003e split bolt connector, 350 MCM split bolt, 4\/0 AWG split bolt, brass split bolt connector, heavy duty electrical splice, UL listed split bolt, ANSI C119.4 connector\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge conductor range:\u003c\/strong\u003e Supports copper conductors from \u003cstrong\u003e350 MCM to 4\/0 AWG SOL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision-engineered brass construction:\u003c\/strong\u003e Ensures excellent conductivity and mechanical strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh clamping force:\u003c\/strong\u003e Maintains stable electrical contact with minimized resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant finishes:\u003c\/strong\u003e Available in tin-plated or nickel-plated variants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90°C temperature rating:\u003c\/strong\u003e Suitable for high-load electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry certified:\u003c\/strong\u003e UL Listed, ANSI C119.4, and NEC compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eHigh-strength brass (CuZn alloy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eConductor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e350 MCM – 4\/0 AWG (SOL), copper conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eSurface Treatment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eTin-plated or nickel-plated for corrosion resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eUp to 90 °C (194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eLow- and medium-voltage electrical systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eMechanical Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eHigh tensile strength for sustained clamping force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e5e7eb;\"\u003eUL Listed, ANSI C119.4, NEC Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSplicing and terminating large-gauge conductors in power distribution networks\u003c\/li\u003e\n\u003cli\u003eElectrical system expansions and upgrades in commercial and industrial facilities\u003c\/li\u003e\n\u003cli\u003eHigh-load circuits in utility, transportation, and renewable energy systems\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant connections for outdoor and high-humidity environments\u003c\/li\u003e\n\u003cli\u003eGrounding and bonding applications in electrical and telecommunication systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVerify conductor sizes fall within the 350 MCM to 4\/0 SOL range before installation.\u003c\/li\u003e\n\u003cli\u003eClean conductors thoroughly to remove oxidation and surface contaminants.\u003c\/li\u003e\n\u003cli\u003eTighten the split bolt evenly to ensure proper clamping force.\u003c\/li\u003e\n\u003cli\u003eApply insulation or protective covering after installation as required by NEC and local codes.\u003c\/li\u003e\n\u003cli\u003eFollow all applicable electrical standards and project specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e1) What conductor sizes does this split bolt connector support?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis connector supports copper conductors from \u003cstrong\u003e350 MCM to 4\/0 AWG solid\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e2) What material is used in this connector?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe connector is manufactured from \u003cstrong\u003ehigh-strength brass (CuZn alloy)\u003c\/strong\u003e for conductivity and durability.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e3) Is this connector UL Listed?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. This split bolt connector is \u003cstrong\u003eUL Listed\u003c\/strong\u003e and compliant with ANSI C119.4 and NEC requirements.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e4) What finish options are available?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eFinish options include \u003cstrong\u003etin-plated\u003c\/strong\u003e and \u003cstrong\u003enickel-plated\u003c\/strong\u003e for corrosion resistance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e5) What temperature rating does this connector have?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThis connector is rated for continuous operation up to \u003cstrong\u003e90°C (194°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e6) Is this suitable for outdoor installations?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes, when properly insulated and installed in accordance with NEC and environmental requirements.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e7) Does it provide a low-resistance electrical connection?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. High clamping force and precision threads help minimize resistance and maintain stable electrical contact.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e8) What tools are required for installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eStandard electrical hand tools are typically sufficient for installation and tightening.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e9) Can this connector be reused?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eReuse may be possible depending on condition and application, but replacement is recommended for critical installations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e10) Is this connector insulated?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. Split bolt connectors are uninsulated and must be insulated after installation if required.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e11) Can this connector be used for grounding and bonding?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. It is commonly used for grounding and bonding applications where permitted by design and electrical code.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003e\u003cstrong\u003e12) How do I select the correct split bolt size?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eSelect the connector based on the largest and smallest conductors being joined. Conversions Tech can assist with proper selection.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003chr\u003e\n\u003cp style=\"font-size: 0.9em; color: #6b7280;\"\u003e© Conversions Tech. All rights reserved.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Conversions Tech","offers":[{"title":"Default Title","offer_id":44665673416756,"sku":"610-35040","price":10.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/split-bolt-connector-350-mcm-max-4-0-awg-min-1157095937.jpg?v=1745384287"}],"url":"https:\/\/conversionstech.com\/collections\/split-bolt-connectors-copper-alloy-16-awg-500-mcm-conversions-tech.oembed","provider":"Conversions Tech","version":"1.0","type":"link"}