{"product_id":"3-30-a-ignition-protected-marine-breakers-and-300-a-battery-switches-ct-mcb-ip","title":"3–30 A Ignition-Protected Marine Circuit Breakers and 300 A Battery Disconnect Switches | CT-MCB-IP","description":"\u003cp style=\"border-left:4px solid #E8742A;background:#F8F7F5;padding:12px 16px\"\u003e\u003cstrong\u003eAt a glance:\u003c\/strong\u003e Push-to-reset 3–30 A ignition-protected marine circuit breakers, UL Listed to UL 1077 and UL 1500, and 300 A battery disconnect switches that meet UL 1500 and SAE J1171, IP66. Sold each.\u003c\/p\u003e\n\u003cp\u003ePrice coming soon. Request a quote. Sold each.\u003c\/p\u003e\n\u003cp\u003eCircuit protection and battery isolation for boats and RVs. The push-to-reset breakers cover 3–30 A, 125\/250 VAC and 32\/50 VDC, with a 1,000 A interrupting rating at 125\/250 VAC, a bakelite body and trip-free cycling. They are UL Listed to UL 1077 and ignition-protected to UL 1500. The battery-switch family is a 300 A continuous disconnect — on\/off, 4-position 1-2-both-off, dual-circuit and dual-circuit-plus — with published cranking and intermittent ratings, IP66 protection, and ignition protection to UL 1500 and SAE J1171. Each breaker and each switch is sold individually.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePush-to-reset breakers, 3–30 A, 125\/250 VAC and 32\/50 VDC, 1,000 A interrupting rating (UL 1077)\u003c\/li\u003e\n\u003cli\u003eBakelite body, 850 °C glow-wire, trip-free cycling\u003c\/li\u003e\n\u003cli\u003eUL Listed to UL 1077 and UL 1500 ignition protection\u003c\/li\u003e\n\u003cli\u003e300 A continuous battery switches, with published 500 A intermittent and 900 A cranking ratings on the on\/off and 4-position models\u003c\/li\u003e\n\u003cli\u003eIP66; meets UL 1500, SAE J1171, ABYC battery-switch requirements, ISO 8846, CE and RoHS\u003c\/li\u003e\n\u003cli\u003eOn\/off, 4-position 1-2-both-off, dual-circuit and dual-circuit-plus constructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker type\u003c\/th\u003e\n\u003ctd\u003eUnipolar, push-to-reset, thermal, trip-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker current range\u003c\/th\u003e\n\u003ctd\u003e3–30 A (exact ampere steps to be confirmed on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker voltage\u003c\/th\u003e\n\u003ctd\u003e125\/250 VAC; 32\/50 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker interrupting rating\u003c\/th\u003e\n\u003ctd\u003e1,000 A at 125\/250 VAC (UL 1077)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker body\u003c\/th\u003e\n\u003ctd\u003eBakelite; 850 °C glow-wire test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker dielectric test (published)\u003c\/th\u003e\n\u003ctd\u003e1,500 VAC \/ min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker current test (published)\u003c\/th\u003e\n\u003ctd\u003e200 % current, 100 % inspected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker certifications\u003c\/th\u003e\n\u003ctd\u003eUL Listed to UL 1077 and UL 1500 ignition protection. CSA and other published marks will be shown once certificates are on file.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch continuous rating\u003c\/th\u003e\n\u003ctd\u003e300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch intermittent \/ cranking\u003c\/th\u003e\n\u003ctd\u003eOn\/off and 4-position: 500 A for 5 min, 900 A for 30 s. Dual-circuit and dual-circuit-plus: 450 A for 5 min, 675 A for 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch voltage\u003c\/th\u003e\n\u003ctd\u003eOn\/off model: 48 V DC maximum. 4-position, dual-circuit and dual-circuit-plus: 32 V DC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch terminals\u003c\/th\u003e\n\u003ctd\u003eTin-plated copper, 3\/8-16 (M10) × 7\/8 in; 120 in-lb (13.56 N·m); 4\/0 AWG (120 mm²) to meet the ratings; cable clearance 1.12 in (28.45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch enclosure\u003c\/th\u003e\n\u003ctd\u003eIP66; isolating cover with snap-off side pieces for rear wire access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch unit size \/ weight (published)\u003c\/th\u003e\n\u003ctd\u003eSelling unit 3.14 × 3.07 × 3.46 in (8 × 7.8 × 8.8 cm); 0.83 lb (0.38 kg). Master carton 48 pieces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery switch certifications\u003c\/th\u003e\n\u003ctd\u003eMeets UL 1500 and SAE J1171 ignition protection; ABYC battery-switch requirements; ISO 8846; CE; RoHS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCatalog numbers (proposed)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-03\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 3 A (rating within the published 3–30 A range; exact steps to be confirmed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-05\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 5 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-10\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 10 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-15\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 15 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 20 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-25\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 25 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-MCB-IP-30\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eIgnition-protected push-to-reset breaker, 30 A (confirm on the published ampere list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-BSW-300-2POS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A continuous single-circuit on\/off battery switch, 48 V DC max, 900 A crank \/ 500 A intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-BSW-300-4POS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A continuous 4-position (1-2-both-off) battery switch, 32 V DC max, 900 A crank \/ 500 A intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-BSW-300-DUAL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A continuous dual-circuit battery switch, 32 V DC max, 675 A crank \/ 450 A intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"ct-pn\"\u003eCT-BSW-300-DUALPLUS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e300 A continuous dual-circuit-plus battery switch, 32 V DC max, 675 A crank \/ 450 A intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAmpere steps inside the published 3–30 A breaker range (3, 5, 10, 15, 20, 25 and 30 A) are typical proposed steps and will be confirmed on the published ampere list. Photographs in this listing show the 300 A battery switch only; a cleaned breaker photograph is not yet available. A 25–300 A surface-mount thermal-breaker family is omitted until a data sheet is on file.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarine panels, battery packs, winches, pumps and refrigeration circuits (breakers)\u003c\/li\u003e\n\u003cli\u003eBattery isolation and 1-2-both-off selection on boats and RVs (switches)\u003c\/li\u003e\n\u003cli\u003eInstallations that require ignition-protected components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBreaker: one push-to-reset circuit breaker\u003c\/li\u003e\n\u003cli\u003eBattery switch: one switch with isolating cover, as published\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpec sheet: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/CT-MCB-IP_CT-BSW-300_Marine_Breakers_and_Battery_Switches_Data_Sheet.pdf?v=1794929659\" target=\"_blank\" rel=\"noopener\"\u003eCT-MCB-IP \/ CT-BSW-300 marine breakers and battery switches data sheet (PDF)\u003c\/a\u003e. Quote only: \u003ca href=\"\/pages\/get-a-quote\"\u003erequest pricing\u003c\/a\u003e or call (307) 206-0534.\u003c\/p\u003e","brand":"Conversions Tech","offers":[{"title":"CT-MCB-IP-03","offer_id":68063739281460,"sku":"CT-MCB-IP-03","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-05","offer_id":68063739314228,"sku":"CT-MCB-IP-05","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-10","offer_id":68063739346996,"sku":"CT-MCB-IP-10","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-15","offer_id":68063739379764,"sku":"CT-MCB-IP-15","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-20","offer_id":68063739412532,"sku":"CT-MCB-IP-20","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-25","offer_id":68063739445300,"sku":"CT-MCB-IP-25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-MCB-IP-30","offer_id":68063739478068,"sku":"CT-MCB-IP-30","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-BSW-300-2POS","offer_id":68063739510836,"sku":"CT-BSW-300-2POS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-BSW-300-4POS","offer_id":68063739543604,"sku":"CT-BSW-300-4POS","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-BSW-300-DUAL","offer_id":68063739576372,"sku":"CT-BSW-300-DUAL","price":0.0,"currency_code":"USD","in_stock":true},{"title":"CT-BSW-300-DUALPLUS","offer_id":68063739609140,"sku":"CT-BSW-300-DUALPLUS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/3-30-a-ignition-protected-marine-circuit-breakers-and-300-a-battery-disconnect-switches-ct-mcb-ip-1267669387.jpg?v=1794935651","url":"https:\/\/conversionstech.com\/products\/3-30-a-ignition-protected-marine-breakers-and-300-a-battery-switches-ct-mcb-ip","provider":"Conversions Tech","version":"1.0","type":"link"}