{"product_id":"mpo-to-mpo-lc-fiber-optic-cable-om3-om4-om5-8-12core-multi-mode-patch","title":"MPO to MPO\/LC Fiber Optic Cable OM3\/OM4\/OM5 8\/12Core Multi-Mode Patch Trunk Jumper Cord | DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200007635#10M","description":"\u003cdiv itemtype=\"https:\/\/schema.org\/Product\" itemscope=\"\"\u003e\n\n\u003cp itemprop=\"description\"\u003eHigh-density multimode assemblies built on \u003cstrong\u003eCorning® ClearCurve® 50\/125 μm\u003c\/strong\u003e bend-insensitive fiber with \u003cstrong\u003eDuPont™ Kevlar®\u003c\/strong\u003e aramid strength members. Low-insertion-loss \u003cstrong\u003eMPO\/UPC female (pinless)\u003c\/strong\u003e connectors, \u003cstrong\u003eLSZH 3.0 mm jacket\u003c\/strong\u003e, default \u003cstrong\u003eType-B polarity\u003c\/strong\u003e, and color coding for OM3 (Aqua), OM4 (Magenta), and OM5 (Lime Green). Available as straight MPO trunks or MPO-to-LC\/SC\/FC\/ST breakouts.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical:\u003c\/strong\u003e IL ≤0.35 dB max (≤0.30 dB typ); RL ≥30 dB (MMF) @ 850\/1300 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend radius:\u003c\/strong\u003e ≥10 mm (fiber core), ≥7.5 mm (jacket)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensile:\u003c\/strong\u003e 80 N short-term pull with Kevlar® reinforcement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e RoHS, CE (EN 50575 CPR), ISO 9001, WEEE, EIA\/TIA, Telcordia GR-326-CORE, TIA-605-4 (FOCIS-5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal:\u003c\/strong\u003e −10 to +70 °C operating; −40 to +85 °C storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eMPO\/UPC \u003cstrong\u003efemale\u003c\/strong\u003e (pinless), low-insertion-loss ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFiber Type\u003c\/th\u003e\n\u003ctd\u003e50\/125 μm multimode (OM3 \/ OM4 \/ OM5) — Corning® ClearCurve®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePolarity (Default)\u003c\/th\u003e\n\u003ctd\u003eType B (straight-through)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWavelengths\u003c\/th\u003e\n\u003ctd\u003e850 nm \/ 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion Loss\u003c\/th\u003e\n\u003ctd\u003e≤0.35 dB (≤0.30 dB typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReturn Loss\u003c\/th\u003e\n\u003ctd\u003e≥30 dB (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJacket\u003c\/th\u003e\n\u003ctd\u003eLSZH, OD 3.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStrength Member\u003c\/th\u003e\n\u003ctd\u003eDuPont™ Kevlar® aramid yarn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBend Radius\u003c\/th\u003e\n\u003ctd\u003eCore ≥10 mm · Jacket ≥7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTensile Strength\u003c\/th\u003e\n\u003ctd\u003e80 N (short-term)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e−10 to +70 °C (14–158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e−40 to +85 °C (−40–185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Counts\u003c\/th\u003e\n\u003ctd\u003e8 \/ 12 \/ 16 \/ 24 \/ 32 \/ 48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakout (Fan-out)\u003c\/th\u003e\n\u003ctd\u003eMPO to LC\/SC\/FC\/ST; default LC branch 0.6–1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength (Std. If you’re unsure, confirm polarity and gender with your network tech before ordering—incorrect mapping will impair link performance.\n\n\u003cp\u003e\u003ca href=\"\/pages\/request-quote\"\u003eConfigure \u0026amp; Quote\u003c\/a\u003e  |  \u003ca href=\"\/pages\/request-sample\"\u003eRequest Sample\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat’s included with a breakout assembly?\u003c\/summary\u003e\n\u003cdiv\u003eMPO trunk with factory fan-out to LC\/SC\/FC\/ST; default LC branch length is 0.6–1.0 m (custom on request).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eFemale vs male MPO—what’s the difference?\u003c\/summary\u003e\n\u003cdiv\u003eFemale is \u003cem\u003epinless\u003c\/em\u003e with alignment holes; male has alignment pins. Match gender to your transceivers\/cassettes.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy is Type-B polarity the default?\u003c\/summary\u003e\n\u003cdiv\u003eType B preserves straight-through lane mapping common to cassette\/transceiver systems; Types A\/C are available.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eExpected loss in the field?\u003c\/summary\u003e\n\u003cdiv\u003eSpec ≤0.35 dB per mated pair (≤0.30 dB typical). Total link loss depends on length and number of mated pairs.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the fiber bend-insensitive?\u003c\/summary\u003e\n\u003cdiv\u003eYes—Corning® ClearCurve® MMF improves margin in dense routing and tight trays.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eSR4\/SR8 transceiver support?\u003c\/summary\u003e\n\u003cdiv\u003eYes—match core count\/lane mapping (8-fiber for SR4, 16-fiber for SR8) and confirm polarity\/keying.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eKeying (Key-Up\/Key-Down) requirements?\u003c\/summary\u003e\n\u003cdiv\u003eType-B trunks typically use Key-Up to Key-Up. If your hardware differs, specify keying in the PO.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I mix OM classes?\u003c\/summary\u003e\n\u003cdiv\u003ePossible but not recommended; performance follows the lowest OM class on the path.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre test reports provided?\u003c\/summary\u003e\n\u003cdiv\u003eSerialized IL\/RL results and end-face inspection images available on request.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eMinimum bend radius?\u003c\/summary\u003e\n\u003cdiv\u003e≥10 mm at the fiber core and ≥7.5 mm at the jacket to minimize micro-bend loss.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003ePulling\/tensile guidance?\u003c\/summary\u003e\n\u003cdiv\u003e80 N short-term. Use proper pulling grips and avoid exceeding limits; never pull on connectors.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the jacket halogen-free?\u003c\/summary\u003e\n\u003cdiv\u003eYes—LSZH (Low Smoke Zero Halogen) for improved life-safety in occupied spaces.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eOperating\/storage temperature?\u003c\/summary\u003e\n\u003cdiv\u003eOperating −10 to +70 °C; storage −40 to +85 °C.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eArmored options?\u003c\/summary\u003e\n\u003cdiv\u003eAvailable on request for higher crush resistance and pathway sharing.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCleaning \u0026amp; inspection?\u003c\/summary\u003e\n\u003cdiv\u003eAlways inspect → clean → inspect. Use MPO-compatible click-cleaners and scopes; never mate dirty end-faces.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eOptical budget tips?\u003c\/summary\u003e\n\u003cdiv\u003eSum fiber attenuation and all mated-pair losses; keep below transceiver budget with margin for aging\/contamination.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eLabeling\/color boots?\u003c\/summary\u003e\n\u003cdiv\u003eWe can supply color boots, laser-etched IDs, heat-shrink, and QR codes matched to your rack map.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eStandards compliance?\u003c\/summary\u003e\n\u003cdiv\u003eRoHS, CE EN 50575 (CPR), ISO 9001, WEEE, EIA\/TIA, Telcordia GR-326-CORE, TIA-605-4 (FOCIS-5).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCustom fan-out lengths\/stagger?\u003c\/summary\u003e\n\u003cdiv\u003eYes—provide panel model and desired branch lengths; we’ll build to spec.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eLead times?\u003c\/summary\u003e\n\u003cdiv\u003eCommon OM4\/Type-B 12\/24-fiber builds are typically quick-ship; customizations may add production days.\u003c\/div\u003e\n\u003c\/details\u003e\n   \n\n\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Conversions Tech","offers":[{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 10M","offer_id":47111757463604,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200007635#10M","price":41.37,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 15M","offer_id":47111757496372,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200007637#15M","price":53.88,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 3M","offer_id":47111757529140,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200006478#3M","price":23.52,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 5M","offer_id":47111757561908,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200007633#5M","price":28.88,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 1M","offer_id":47111757594676,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:4#1M","price":18.76,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 2M","offer_id":47111757627444,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200004335#2M","price":21.14,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 50M","offer_id":47111757660212,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:201285105#50M","price":140.82,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 100M","offer_id":47111757692980,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:201299124#100M","price":265.29,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 20M","offer_id":47111757725748,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200025003#20M","price":65.8,"currency_code":"USD","in_stock":false},{"title":"MPO-MPO-OM4-8Core \/ CHINA \/ 30M","offer_id":47111757758516,"sku":"DUP-14:200001951#MPO-MPO-OM4-8Core;200007763:201336100;380:200136360#30M","price":90.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0291\/8445\/8804\/files\/mpo-to-mpo-lc-fiber-optic-cable-om3-om4-om5-8-12core-multi-mode-patch-trunk-jumper-cord-40gb-100gb-female-type-b-upc-lszh-jacket-1193885145.webp?v=1758437393","url":"https:\/\/conversionstech.com\/products\/mpo-to-mpo-lc-fiber-optic-cable-om3-om4-om5-8-12core-multi-mode-patch","provider":"Conversions Tech","version":"1.0","type":"link"}