12V Inline Fuse Block Heavy Duty 200 Amp Mini ANL Fuse Holder Car Audio Marine Truck Assortment Kit Car Fuses Plastic Material
Shipping calculated at checkout
SKU: 208844449:5557472#48 V;209018456:-4#200A
47 in stock
Fuse Block — 200 A ANL Included, 48 V DC / 200 V AC, UL94-V0 Base, 2×M8 Studs
Heavy-duty ANL fuse holder with a UL94-V0 glass-reinforced thermoplastic base and a clear polycarbonate cover. Includes a gold-plated 200 A ANL fuse with viewing window for quick status checks. Tin-plated copper bus, 2 × M8 studs, and through-hole mounting make it a reliable choice for automotive, marine, RV, audio, and DC power distribution up to 48 V DC / 200 V AC.
- Includes: 200 A ANL fuse (windowed, gold-plated)
- Base / Cover: UL94-V0 glass-reinforced nylon + clear polycarbonate
- Bus / Contacts: Tin-plated pure copper for low resistance
- Terminals: 2 × M8 studs; nut + washer set for solid lug contact
- Mount: Through-hole; plug-in ANL for fast service
-
Fuse range: Accepts common ANL ratings (e.g. The “continuous 1500 A” figure is a vendor declaration and not the installed current rating — treat as a mechanical/withstand claim only. Always size the fuse to the smallest conductor and application inrush; verify prospective fault current and thermal rise.
Package Contents
- 1 × ANL fuse block (base + clear cover, 2 × M8 studs)
- 1 × ANL 200 A fuse (gold-plated, viewing window)
- Stud nuts & washers; mounting screws (as supplied)
Install Notes: Mount near the source (battery/bus) to minimize unprotected length. Use ring lugs sized for M8 hardware and cable gauge. Torque per lug manufacturer spec; re-torque after initial thermal cycles. For harsh environments, add heat-shrink boots or place inside a sealed enclosure. This is a low breaking-capacity class — select fuses appropriate to the system’s prospective fault current.
Request a Quote | Request Sample
FAQs
What fuse format does this holder use?
Standard ANL bolt-down fuses. A 200 A ANL is included; other ratings (e.g., 50–500 A) are supported.What system voltage is supported?
Up to 48 V DC or 200 V AC maximum.Are the studs M8?
Yes — 2 × M8 terminal studs for the input and output lugs.Is a protective cover included?
Yes — clear polycarbonate cover for touch protection and quick fuse status view.Does the block really support 1500 A continuous?
No — treat that as a vendor mechanical/withstand claim. Actual current is limited by the installed fuse rating, wiring ampacity, and thermal limits.Where should I mount the fuse block?
As close to the power source as practical to minimize unprotected cable length; fasten to a flat, rigid surface.Is it suitable for marine or RV applications?
Yes — commonly used in boats and RVs. For salt/exposed areas, use corrosion-resistant lugs and additional sealing.What tools/torque should I use on the studs?
Follow the ring-lug manufacturer’s torque spec for M8 hardware; re-torque after initial heat cycles.Is this a high interrupt-rating device?
No — it’s a low breaking-capacity class. Choose ANL fuse ratings that match your system’s fault studies.Can I parallel two lugs on a stud?
One lug per stud is preferred for contact integrity. If stacking is unavoidable, confirm clamp pressure and temperature rise.What’s included with the 200 A fuse?
A gold-plated ANL 200 A fuse with a clear window to identify a blown element quickly.Will it accept Mini-ANL fuses?
No — this holder is for full-size ANL. Mini-ANL (MIDI) uses a different footprint and holder.How do I check a blown fuse?
Visual check through the window, then verify with a meter. Identify and correct the cause before replacing.Is the base flame-retardant?
Yes — the base is UL94-V0 rated glass-reinforced thermoplastic.What conductor sizes are typical?
Commonly 1/0, 2, 4, and 8 AWG — select ring lugs sized for the cable and M8 hardware.Is the holder waterproof?
The cover provides touch protection but the assembly is not IP-rated. Use a sealed enclosure for wet locations.Can I use this on lithium battery systems?
Yes — verify BMS behavior, available fault current, and inrush. Select the appropriate ANL rating/curve.What’s the operating temperature?
−40 °C to +85 °C.Do you offer spare fuses?
Yes — ANL fuses from 50 A to 500 A are available separately. Match rating to your wiring and load.Can I order with my own logo?
Yes — OEM/ODM labeling and custom packs are available on request.Warranty & support?
12-month limited warranty on the holder; fuses are consumables. Contact support with your order ID.
4 Reasons Pros Buy Direct from Conversions Tech
, we design, test, and ship every product from inside the United States— “” quality without the big-box markup.
Our , mold, and QA station behind our weatherproof boxes, conduit bodies, and power inverters. , UL-listed safety, and up to 30 % lower cost than .
Need a torque spec or an OEM quote at dawn? You’ll speak directly with the Conversions Tech engineering desk—not a script reader—for instant answers, custom kitting, and private-label options.
Bottom line: For rugged, code-compliant electrical solutions shipped fast from a trusted U.S. source, choose Conversions Tech and build it right the first time.