PPE for the trades that work near energized equipment.

Rubber insulating gloves in Class 00 and Class 0 with leather protectors, arc-rated shirts and face shields for NFPA 70E categories 1 and 2, Class E dielectric hard hats, ANSI Z87.1 eye protection, ANSI 107 Class 2 hi-vis, electrical lockout-tagout kits, 1000 V VDE insulated hand tools, cut-resistant work gloves, traffic cones and vehicle safety gear. Sold by the pair, the case or the crew; contractor and fleet pricing; same-day shipping on in-stock items.

Choosing insulating gloves

Class Max use voltage Typical work
Class 00 500 V AC / 750 V DC Residential and light commercial, 120/240 and 208 V panels, solar strings under 750 V DC
Class 0 1,000 V AC / 1,500 V DC 480 V commercial and industrial, 1,500 V PV, EV and battery systems
Class 1 to 4 7.5 kV to 36 kV Utility and line work, ordered to spec

Rubber gloves are shock protection only. Wear leather protectors over them for cuts, abrasion and arc exposure; the protector also extends the rubber glove's life. Inspect by inflation before every use, and have them dielectrically retested every six months per OSHA 1910.137. Bi-color black-over-yellow gloves make cuts visible on inspection.

Arc flash in one paragraph

Insulated gloves stop shock; arc-rated clothing stops the heat of an arc, measured in cal/cm². NFPA 70E PPE Category 1 is 4 cal, Category 2 is 8 cal, which covers most 480 V panel work with the door open. An 8 cal long-sleeve shirt, a 12 cal face shield on a Class E hard hat, safety glasses and voltage-rated gloves is the standard Category 2 kit. Lockout-tagout comes first; PPE is for the exposure LOTO can't remove, which is testing and troubleshooting live.

Related: electrician tools · work lights and safety lighting · solar and 1,500 V PV · contractor pricing

6 products

  • On Sale

  • On Sale

  • On Sale

Safety & PPE FAQ

1. What products are in this collection?

Cut-resistant and nitrile safety gloves, ANSI Z87.1 safety glasses, ANSI Z89.1 hard hats, hi-vis vests & jackets (ANSI/ISEA 107), disposable & reusable respirators, ear plugs (NRR-rated), face shields, and ready-to-ship PPE kits.

2. Which standards do Conversions Tech gloves meet?

Our cut gloves are tested to ANSI/ISEA 105-2024 with ratings from A2 to A6; chemical-resistant nitrile options pass EN 374 and ASTM D6319.

3. What does “cut level A4” mean?

Under ANSI/ISEA 105, A4 indicates the glove withstands 1,500–2,199 grams of blade force before cutting through—ideal for sheet-metal or glass handling.

4. Are the nitrile gloves powder-free and latex-free?

Yes—100 % synthetic nitrile with a chlorinated interior for easy donning, suitable for latex-sensitive users and clean applications.

5. Do your safety glasses meet ANSI Z87.1-2020?

Every lens is impact-tested (high-mass & high-velocity) and stamped “Z87+”, offering UV 400 protection and anti-fog coatings.

6. What hard-hat classes do you offer?

Type I, Class E (20 kV electrical) and Type II, Class C vented caps—both with six-point ratchet suspensions.

7. Are hi-vis garments ANSI/ISEA 107 compliant?

Yes—Class 2 vests for roadside crews and Class 3 jackets for full-coverage visibility in low-light zones.

8. How do I pick the right glove size?

Measure palm circumference; XS = 6–7″, S = 7–8″, M = 8–9″, L = 9–10″, XL = 10–11″, 2XL = 11–12″. All gloves follow this numeric chart.

9. Do you offer bulk-order discounts?

Yes—tiered pricing starts at 10 packs; pallet-level orders (≥10,000 gloves or 500 vests) qualify for 15 % off and free freight in the continental U.S.

10. Can I add my company logo?

Absolutely—screen printing for vests & hard hats or pad printing for safety glasses with MOQs of 200 units; typical turnaround 7-10 business days.

11. What’s the shelf life of disposable nitrile gloves?

Five years when stored below 100 °F (38 °C) and away from UV light; each box is date-coded.

12. Are any products FDA food-contact safe?

Blue nitrile gloves and clear poly gloves are FDA 21 CFR Part 177 compliant for food handling.

13. What’s the difference between disposable and reusable respirators?

Disposable N95s filter ≥95 % of 0.3 µm particles for single-shift use; reusable half-mask elastomers pair with P100 or OV cartridges for longer service life and chemical protection.

14. What Noise-Reduction Rating do your ear plugs carry?

Expandable foam plugs are NRR 33 dB; silicone flanged plugs are NRR 26 dB and reusable 100+ insertions.

15. How do I clean and store PPE?

Gloves: machine-wash cold, air-dry. Glasses & face shields: mild soap + microfiber cloth. Hard hats: wipe with non-solvent cleaner; replace after major impact or five years.

16. What are your shipping lead times?

Stock PPE ships same-day if ordered by 3 PM PT; custom-logo items add 3–5 days. West-coast ground: 1-2 days • East-coast: 4-5 days.

17. What warranty & returns do you offer?

30-day money-back guarantee plus one-year workmanship warranty on reusable PPE (hard hats, glasses, respirators).

18. Are your gloves completely latex-free?

Yes—no natural-rubber latex in liners or coatings, reducing allergy risk.

19. Can you supply full PPE starter kits?

Yes—bundle gloves, glasses, vest, ear plugs, and hard hat in a branded zip bag; ideal for site visitors or new-hire onboarding.

20. Where can I download spec sheets & SDS files?

Download the master PDF—cut ratings, ANSI certificates, chemical-resistance charts, and Safety-Data Sheets included.