Skip to content

Conversions Tech Bulk Cable

Conversions Tech inc is your one-stop source for premium bulk cable spools engineered for residential, commercial, and industrial low-voltage networks. From 3 GHz quad-shield RG6 coax to 23 AWG Cat6A plenum, every reel is UL or ETL verified, footage-marked, and ready for PoE++, 4K SDR/12G-SDI, MoCA, and 10 GbE deployments.

  • Ethernet: Solid-copper Cat5e, Cat6, Cat6A, and shielded Cat7—CMP, CMR, UV-PE & gel-filled direct-burial.
  • Coax: RG6, RG11, and HD-SDI RG59—sweep-tested 5 MHz-3 GHz for satellite, cable, and CCTV.
  • Specialty: 18/2-18/8 thermostat CL2/CL3, 12/2 & 14/4 OFC speaker wire, clearly labeled CCA economy line.
  • Fiber Optic: OS2 single-mode & OM3/OM4 multimode trunks, armored or indoor plenum LSZH.

Whether you’re trenching direct-burial Cat6A to a security gate, pulling CMP Cat6 in a high-rise plenum, or running low-loss RG11 for a head-end, Conversions Tech inc delivers high-bandwidth, code-compliant bulk cable with same-day shipping from U.S. warehouses.

Bulk Cable FAQ | Conversions Tech inc — RG-6 Coax, Cat5e-Cat7, Thermostat, Speaker, CCA, Fiber Optic

Bulk Cable FAQ – Coax | Cat5e-Cat7 | Thermostat | Speaker | CCA | Fiber Optic

1. What’s the attenuation of your RG6 quad-shield at 1 GHz?
6.3 dB per 100 ft—ideal for 4K satellite and DOCSIS 3.1 head-ends.
2. Is RG11 better than RG6 for long 4K HDMI extenders?
Yes—larger 14 AWG center, 4.3 dB/100 ft @ 1 GHz; recommended for >150 ft backbone runs.
3. Do your coax spools support MoCA 2.5 whole-home networking?
Absolutely—sweep-tested through 3 GHz with < −20 dB return loss in the 1175–1675 MHz MoCA band.
4. RG59 vs RG6 for 12G-SDI 4K broadcast?
Use our 18 AWG RG6 precision video (Belden 1694 equiv.)—meets SMPTE ST-2082 12 Gb/s up to 262 ft.
5. Max distance for Cat6 10 GbE?
55 m per TIA. For full 100 m 10 GbE, choose Cat6A 23 AWG S/FTP.
6. Shielded vs unshielded Cat6—when do I need F/UTP?
Use shielded in high-EMI zones (UPS rooms, hospitals) or when bundling 24+ PoE++ lines to reduce crosstalk & heat.
7. Does your outdoor direct-burial Cat6A have gel fill?
Yes—PE jacket + flooding compound blocks moisture; UV-black rated 20-year sun exposure.
8. Can Cat7 RJ45 cables do 40 GbE?
With GG45/TERA connectors, Cat7A (1000 MHz) supports 40 Gb/s to 30 m—our RJ45-terminated version runs 25 GbE flawlessly.
9. What’s the temp rating on plenum CMP Cat6A?
−20 °C to +75 °C; FEP jacketing meets NFPA 262 low-smoke.
10. Loop resistance of 23 AWG Cat6A for PoE++ 90 W?
≤ 0.44 Ω/100 m, meeting IEEE 802.3bt Type 4 requirements.
11. Is CCA cable UL listed?
No—CCA is ETL-verified for low-voltage but not UL; we mark reels clearly to keep life-safety circuits pure copper.
12. Can I run 4K IP cameras on Cat6 CCA?
Yes for PoE < 30 W and < 60 m, but solid copper is advised for long powered runs.
13. CL2 vs CL3 rated speaker wire?
CL3 handles 300 V surge vs 150 V for CL2—choose CL3 for distributed-audio 70 V systems.
14. Do you sell 16/4 in-wall speaker cable with ripcord?
Yes—16 AWG OFC, white CMP or CMR jacket, nylon ripcord for easy strip.
15. Thermostat cable color code?
Standard: R-red, C-blue, Y-yellow, W-white, G-green; our jackets print legend every 12 in.
16. What’s the max 10 Gb reach on OM3 vs OM4?
OM3 300 m @ 850 nm; OM4 400 m. Our aqua OM3 and magenta OM4 exceed ISO/IEC 11801.
17. Is bend-insensitive OS2 available?
Yes—G.657.A2 fiber ≤ 0.15 dB loss @ 1550 nm with 10 mm bend radius.
18. Armored fiber crush rating?
1500 N/100 mm; steel interlock armor protects against rodents & forklift wheels.
19. Can I mix Cat5e and Cat6 in the same 24-port patch panel?
Yes, but performance drops to the lowest category (Cat5e). Use Cat6 keystones for consistency.
20. What’s the recommended pulling tension for Cat6A?
≤ 25 lbf (110 N). Greater force can deform pair geometry and raise NEXT.
21. Do you pre-register cable footage every 2 ft on jackets?
Yes—sequential foot markers simplify pulls and inventory.
22. Is gel-filled Cat6 shielded against lightning?
Flooding gel blocks moisture; lightning protection depends on proper grounding & surge arrestors.
23. Can RG6 quad-shield be terminated with compression F-type?
Absolutely—use 21 mm strip & our CT-F6 tool for 360° hex-crimp.
24. Do your Cat6 reels support HDBaseT 4K 100 m?
Yes—our solid-copper Cat6 passes PSNEXT > 44 dB etc.; verified with Valens chipset analyzer.
25. Maximum bundle size for PoE to avoid heat rise in plenum?
ANSI/TIA-TSB-184-A: limit 30 cables @ 55 W in 25 °C plenum; our FEP Cat6A dissipates heat 20 % faster.
26. Fiber MPO trunk polarity options?
We supply Type A, B, or C; default is Type B (key-up/key-up) for parallel 40 Gb and 100 Gb links.
27. Does Cat7 need ground bonding at both ends?
Yes—shield must be bonded to patch-panel and switch chassis to control alien crosstalk.
28. Can 22/4 thermostat cable carry RS-485 Modbus?
Yes up to 1200 m @ 9600 bps; twist wires to improve noise immunity.
29. Is your RG6 rated 75 Ω ± 3 Ω?
Correct—impedance window 72–78 Ω measured by VNA.
30. What jacket material is used for low-smoke zero-halogen Cat7?
Halogen-free polyolefin meeting IEC 60754-1 (<0.5 mg HCl per g).
31. Can Cat5e CMR be used outdoors?
Only in conduit; UV exposure will crack PVC. Choose our UV-PE Cat5e Outdoor.
32. What certification do your fiber jumpers carry?
100 % interferometer & OTDR-tested; GR-326-CORE compliant.
33. Do you offer Siamese RG59 + 18/2 power?
Yes—HD-CCTV RG59 + 18/2 annealed copper power conductors in PVC or CMP jacket.
34. Are Cat6A keystone jacks tool-less?
Yes—90 ° punch-down or tool-less IDC, color-coded T568A/B.
35. What’s the typical delay skew on Cat6 bundles?
≤ 45 ns/100 m; our spline design averages 27 ns, ideal for VoIP.
36. Can armored fiber be run in tray without conduit?
Yes—interlock armor replaces metal conduit in NEC 770.113.
37. How do I prep quad-shield coax for compression fittings?
Remove outer jacket, fold outer braid & foil back, trim dielectric ¼ in, insert into F-connector until flush.
38. Are there CMP thermostat cables?
Yes—18/8 & 18/2 plenum thermostat, red CMP jacket.
39. HDMI over Cat6—does your Cat6 support 4K 60 Hz extenders?
Yes—solid copper, <350 MHz NVP ensures ≤ 1 ns/m skew required by HDBaseT.
40. What’s the crush resistance of outdoor Cat6 direct-burial?
≥ 1100 N/100 mm per IEC 60794-1-21.
41. Do you provide wooden or plastic reels?
Wood standard on 1000 ft coax & Cat reels; plastic payout box on 500 ft indoor Cat6.
42. Is PoE safe on CCA Cat5e?
Up to 15 W (802.3af) only; higher loads overheat—use pure copper.
43. Do fiber spools include pulling eyes?
Yes—factory-installed Kevlar pulling grips on ≥1000 ft reels.
44. Can I terminate Cat6A field plugs without a jacket stripper?
Yes—our tool-less field plugs have built-in blade for 1-step jacket flush-cut.
45. Lifetime warranty coverage?
Bulk cables carry lifetime limited warranty covering conductor gauge, sweep bandwidth, and flame rating when installed to TIA-568 & NEC.
© 2025 Conversions Tech inc. All rights reserved.