AC Power Cords | IEC C13, C19, C5, C7 & NEMA 5-15P | PDU, Server, Appliance
The IEC power cord wall, by the box.
NEMA 5-15P to C13 for PCs and monitors, C14 to C13 for PDU-to-server, 12 AWG C20 to C19 for 20 A servers and UPS units, C5 cloverleaf for laptop bricks, figure-8 C7 for TVs and audio, polarized C7 for cable modems and set-top boxes, plus piggyback cords with a pass-through outlet and right-angle C13 extensions for tight rack cabling. 3, 6, and 12 ft. UL Listed, SJT or SPT-2 jacket as marked, bare-copper conductors. Stocked; same-day shipping; case pricing for IT, AV, and OEM buyers.
Pick by the connector on the device
Device inlet
Cord
Rating
Typical use
C14 (3-pin, on PCs, monitors, PDUs)
NEMA 5-15P to C13 or C14 to C13
10 A, 18 AWG
Desktop, monitor, rack gear from a PDU
C20 (larger 3-pin, keyed)
C20 to C19, 12 AWG
20 A, 250 V
Servers, UPS, high-draw switches
C6 cloverleaf (Mickey Mouse)
NEMA 5-15P to C5
7 A
Laptop power bricks, projectors
C8 figure-8 (2-pin, symmetrical)
NEMA 1-15P to C7
7 A
TVs, soundbars, game consoles, printers
C8 polarized (one side squared)
NEMA 1-15P to polarized C7
7 A
Arris and Motorola modems, set-top boxes
Need another outlet at the wall
Piggyback NEMA 5-15P/R to C13
10 A
Monitor + PC on one wall outlet
C13 device in a shallow rack
Right-angle C13 to C14 extension
10 A
Low-profile exit behind switches and PDUs
Gauge, jacket, and length
18 AWG SJT handles 10 A, which covers every C13 device; 12 AWG SJT is required for the 20 A C19/C20 class. SPT-2 is the flat two-conductor jacket on figure-8 cords. Length is a voltage-drop question only at 12 ft on 20 A loads; for everything else pick the shortest cord that reaches, because slack in a rack is a cable-management problem, not a spare.