From Conduit Bodies to Fittings: Building a Complete EMT or Rigid Cart

Start with CT conduit bodies, then add from 144 EMT and rigid fitting SKUs with RACO and Bridgeport style crosses.

Second Source Conduit Bodies When the Supply House Is Out

Use Conversions Tech as a second source for UL Listed conduit bodies when stock or lead time slips. Distributors welcome.

Conduit Body Cheat Sheet for Purchasing Agents (Sizes and List Anchors)

PA cheat sheet for conduit body sizes, list anchors, trade tiers, crosses, and order checklist from Conversions Tech.

Aluminum NEMA 3R Conduit Bodies: Spec Facts That Matter on the Job

UL Listed copper-free aluminum NEMA 3R conduit bodies from Conversions Tech. Facts only, sizes, stock, and trade path.

Threaded vs Set-Screw Conduit Bodies (Rigid/IMC vs EMT)

Choose threaded NPT for rigid and IMC or set-screw for EMT. Series cues, crosses, and stock notes from Conversions Tech.

Form 7 Conduit Bodies Explained for Contractors and PAs

What Form 7 style conduit bodies mean on the job and how Conversions Tech publishes size for size crosses on every page.

LL, LR, C, and T Conduit Bodies: When to Use Each

Choose LL, LR, C, or T conduit bodies for the pull. Threaded and set-screw options with crosses on every Conversions Tech page.

LB17 to LB67 Conduit Body Cross Reference (Form 7 Style)

Size for size Form 7 style LB17 to LB67 crosses. UL Listed aluminum bodies at Conversions Tech. Confirm on each product page.

Why Use Threadless Rigid Compression Fittings Instead of Threading

The case for threadless compression couplings and connectors on rigid and IMC: installed labor cost, joining pipe that cannot rotate, NEC 344.42(B) and 342.42(B), grounding continuity, and where threaded still wins.

Where to Use Rigid Compression Fittings: Application Guide for RMC and IMC

Seven jobsite situations where threadless rigid compression couplings and connectors are the right fitting, the cases where threaded is still required, and a location-by-location spec table.

Rigid Compression Fittings Buyer's Guide: Threadless Couplings and Connectors for RMC and IMC

How threadless compression couplings and connectors work on rigid and IMC conduit, when to use them instead of threaded fittings, sizes 1/2 to 2 inch, UL 514B listing, and Bridgeport and RACO cross references.

Rigid vs EMT Couplings: Threaded, Set-Screw, and Compression — Which Coupling for Which Raceway

EMT set-screw, EMT compression, rigid threaded, and rigid threadless compression couplings: what each joins, why EMT and rigid fittings never interchange (different ODs), and the NEC 344.42 / 358.42 bonding rules.