3–30 A Ignition-Protected Marine Circuit Breakers and 300 A Battery Disconnect Switches | CT-MCB-IP
SKU: CT-MCB-IP-03
In stock
At a glance: Push-to-reset 3–30 A ignition-protected marine circuit breakers, UL Listed to UL 1077 and UL 1500, and 300 A battery disconnect switches that meet UL 1500 and SAE J1171, IP66. Sold each.
Price coming soon. Request a quote. Sold each.
Circuit protection and battery isolation for boats and RVs. The push-to-reset breakers cover 3–30 A, 125/250 VAC and 32/50 VDC, with a 1,000 A interrupting rating at 125/250 VAC, a bakelite body and trip-free cycling. They are UL Listed to UL 1077 and ignition-protected to UL 1500. The battery-switch family is a 300 A continuous disconnect — on/off, 4-position 1-2-both-off, dual-circuit and dual-circuit-plus — with published cranking and intermittent ratings, IP66 protection, and ignition protection to UL 1500 and SAE J1171. Each breaker and each switch is sold individually.
Features
- Push-to-reset breakers, 3–30 A, 125/250 VAC and 32/50 VDC, 1,000 A interrupting rating (UL 1077)
- Bakelite body, 850 °C glow-wire, trip-free cycling
- UL Listed to UL 1077 and UL 1500 ignition protection
- 300 A continuous battery switches, with published 500 A intermittent and 900 A cranking ratings on the on/off and 4-position models
- IP66; meets UL 1500, SAE J1171, ABYC battery-switch requirements, ISO 8846, CE and RoHS
- On/off, 4-position 1-2-both-off, dual-circuit and dual-circuit-plus constructions
Specifications
| Breaker type | Unipolar, push-to-reset, thermal, trip-free |
|---|---|
| Breaker current range | 3–30 A (exact ampere steps to be confirmed on the published ampere list) |
| Breaker voltage | 125/250 VAC; 32/50 VDC |
| Breaker interrupting rating | 1,000 A at 125/250 VAC (UL 1077) |
| Breaker body | Bakelite; 850 °C glow-wire test |
| Breaker dielectric test (published) | 1,500 VAC / min |
| Breaker current test (published) | 200 % current, 100 % inspected |
| Breaker certifications | UL Listed to UL 1077 and UL 1500 ignition protection. CSA and other published marks will be shown once certificates are on file. |
| Battery switch continuous rating | 300 A |
| Battery switch intermittent / cranking | On/off and 4-position: 500 A for 5 min, 900 A for 30 s. Dual-circuit and dual-circuit-plus: 450 A for 5 min, 675 A for 30 s |
| Battery switch voltage | On/off model: 48 V DC maximum. 4-position, dual-circuit and dual-circuit-plus: 32 V DC maximum |
| Battery switch terminals | Tin-plated copper, 3/8-16 (M10) × 7/8 in; 120 in-lb (13.56 N·m); 4/0 AWG (120 mm²) to meet the ratings; cable clearance 1.12 in (28.45 mm) |
| Battery switch enclosure | IP66; isolating cover with snap-off side pieces for rear wire access |
| Battery switch unit size / weight (published) | Selling unit 3.14 × 3.07 × 3.46 in (8 × 7.8 × 8.8 cm); 0.83 lb (0.38 kg). Master carton 48 pieces. |
| Battery switch certifications | Meets UL 1500 and SAE J1171 ignition protection; ABYC battery-switch requirements; ISO 8846; CE; RoHS. |
Catalog numbers (proposed)
| Catalog number | Description |
|---|---|
| CT-MCB-IP-03 | Ignition-protected push-to-reset breaker, 3 A (rating within the published 3–30 A range; exact steps to be confirmed) |
| CT-MCB-IP-05 | Ignition-protected push-to-reset breaker, 5 A (confirm on the published ampere list) |
| CT-MCB-IP-10 | Ignition-protected push-to-reset breaker, 10 A (confirm on the published ampere list) |
| CT-MCB-IP-15 | Ignition-protected push-to-reset breaker, 15 A (confirm on the published ampere list) |
| CT-MCB-IP-20 | Ignition-protected push-to-reset breaker, 20 A (confirm on the published ampere list) |
| CT-MCB-IP-25 | Ignition-protected push-to-reset breaker, 25 A (confirm on the published ampere list) |
| CT-MCB-IP-30 | Ignition-protected push-to-reset breaker, 30 A (confirm on the published ampere list) |
| CT-BSW-300-2POS | 300 A continuous single-circuit on/off battery switch, 48 V DC max, 900 A crank / 500 A intermittent |
| CT-BSW-300-4POS | 300 A continuous 4-position (1-2-both-off) battery switch, 32 V DC max, 900 A crank / 500 A intermittent |
| CT-BSW-300-DUAL | 300 A continuous dual-circuit battery switch, 32 V DC max, 675 A crank / 450 A intermittent |
| CT-BSW-300-DUALPLUS | 300 A continuous dual-circuit-plus battery switch, 32 V DC max, 675 A crank / 450 A intermittent |
Ampere steps inside the published 3–30 A breaker range (3, 5, 10, 15, 20, 25 and 30 A) are typical proposed steps and will be confirmed on the published ampere list. Photographs in this listing show the 300 A battery switch only; a cleaned breaker photograph is not yet available. A 25–300 A surface-mount thermal-breaker family is omitted until a data sheet is on file.
Applications
- Marine panels, battery packs, winches, pumps and refrigeration circuits (breakers)
- Battery isolation and 1-2-both-off selection on boats and RVs (switches)
- Installations that require ignition-protected components
What's in the box
- Breaker: one push-to-reset circuit breaker
- Battery switch: one switch with isolating cover, as published
Spec sheet: CT-MCB-IP / CT-BSW-300 marine breakers and battery switches data sheet (PDF). Quote only: request pricing or call (307) 206-0534.
Why Pros Buy Direct from Conversions Tech
Quality-tested and UL Listed. Every product we carry is built to our specifications by certified manufacturing partners and quality-verified before it ships. UL/CSA listed where required, NEC compliant.
Cross-reference savings. Direct equivalents to Burndy, Hubbell, and other OEM part numbers at up to 30% less — same specs, same certifications, without the big-brand markup.
Real technical support. Need a torque spec, die reference, or an OEM quote? You’ll speak directly with the Conversions Tech engineering desk — not a script reader — for instant answers, custom kitting, and private-label options.
Fast US fulfillment. In-stock items ship same day from Oxnard, CA, by ground or expedited.