5–60 A DIN-Rail and 175/225 A Molded-Case Circuit Breakers, UL 489 | CT-MCB489
SKU: CT-MCB489-1P-15-C
In stock
At a glance: UL Listed, UL 489 branch-circuit breakers: DIN-rail miniature breakers in a published 5–60 A family (catalog numbers here for 15–60 A, Type C, 1/2/3-pole, 10 kA) and 3-pole 175 A and 225 A molded-case breakers, 600 VAC. Sold each.
Price coming soon. Request a quote. Sold each.
A two-family breaker line for North American branch-circuit protection. The DIN-rail miniature breakers cover 5–60 A in 1-, 2- and 3-pole, 120/240 VAC, with a 10 kA interrupting rating, thermal-magnetic Type C trip, and a visible contact-position window. The molded-case family covers 175 A and 225 A, 3-pole, 600 VAC thermal-magnetic units in a 250 A frame, with published interrupting ratings of 100 kA at 240 V, 65 kA at 480 V and 20 kA at 600 V. Both families are UL 489 Listed. Each breaker is sold individually.
Features
- UL Listed to UL 489
- Miniature breakers mount on a standard 35 mm DIN rail; optional feet for front or bottom / surface mounting
- Thermal-magnetic Type C trip (published 6.4–9.6 × In)
- Contact-position indication (green open / red closed) and a lockable handle
- Copper conductors only, 14–4 AWG (2–25 mm²), 3.5 N·m, 60/75 °C wire
- Molded-case 175 A and 225 A, 3-pole, 600 VAC, with line and load lugs
- MCCB published interrupting ratings: 100 kA at 240 V, 65 kA at 480 V, 20 kA at 600 V
Specifications
| Miniature breaker standard | UL 489 |
|---|---|
| MCB poles | 1, 2 or 3 |
| MCB current ratings | 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 and 60 A (published). Website SKUs start at the common 15–60 A sizes; 5, 10, 35 and 45 A are available. |
| MCB voltage | 120/240 VAC (1- and 2-pole); 240 VAC (3-pole) |
| MCB frequency | 50/60 Hz |
| MCB interrupting rating | 10 kA |
| MCB trip | Thermal-magnetic, Type C (6.4–9.6 × In) |
| MCB insulation / impulse | 1,000 VAC rated insulation; 6 kV impulse |
| MCB enclosure rating | IP30 |
| MCB life | 6,000 electrical operations; 10,000 mechanical operations |
| MCB operating temperature | −25 °C to +40 °C (reference 30 °C) |
| MCB altitude | Up to 6,561 ft (2,000 m) |
| MCB wiring | 14–4 AWG Cu only (2–25 mm²), 3.5 N·m, 60/75 °C |
| MCB mounting | 35 mm DIN rail; optional mounting feet for bottom or surface mount |
| MCB width | 1-pole 18.8 mm (0.74 in); 2-pole 37.6 mm (1.48 in); 3-pole 56.4 mm (2.22 in) |
| MCB weight | 1-pole 0.161 kg; 2-pole 0.314 kg; 3-pole 0.467 kg |
| MCCB ratings | 175 A and 225 A, 3-pole, 600 VAC, 250 A frame, thermal-magnetic, with line/load lugs |
| MCCB interrupting (published) | 100 kA at 240 V, 65 kA at 480 V, 20 kA at 600 V |
| MCCB outline / weight (published) | 7.17 × 4.13 × 3.47 in (182 × 105 × 88 mm); 4.41 lb |
| MCCB lugs (published) | #8 AWG–350 kcmil |
| MCCB calibration / environment (published) | 40 °C calibration; operating −40 °C to 70 °C |
| MCCB endurance (published) | 10,000 mechanical / 6,000 electrical operations |
| Certification | UL Listed, UL 489 |
Catalog numbers (proposed)
| Catalog number | Description |
|---|---|
| CT-MCB489-1P-15-C | 1-pole, 15 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-20-C | 1-pole, 20 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-25-C | 1-pole, 25 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-30-C | 1-pole, 30 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-40-C | 1-pole, 40 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-50-C | 1-pole, 50 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-1P-60-C | 1-pole, 60 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-15-C | 2-pole, 15 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-20-C | 2-pole, 20 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-25-C | 2-pole, 25 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-30-C | 2-pole, 30 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-40-C | 2-pole, 40 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-50-C | 2-pole, 50 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-2P-60-C | 2-pole, 60 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-15-C | 3-pole, 15 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-20-C | 3-pole, 20 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-25-C | 3-pole, 25 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-30-C | 3-pole, 30 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-40-C | 3-pole, 40 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-50-C | 3-pole, 50 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCB489-3P-60-C | 3-pole, 60 A, Type C, 120/240 VAC, 10 kA, DIN-rail UL 489 MCB |
| CT-MCCB-3P-175-600 | 3-pole 175 A, 600 VAC, thermal-magnetic MCCB, 250 A frame, with line/load lugs |
| CT-MCCB-3P-225-600 | 3-pole 225 A, 600 VAC, thermal-magnetic MCCB, 250 A frame, with line/load lugs |
Applications
- Panelboards and branch-circuit protection
- HVAC equipment
- UPS, inverters and power-supply circuits
- Industrial control cabinets
- Solar and battery equipment (MCB AC ratings above; a DC miniature-breaker family is also offered — see notes)
What's in the box
- One circuit breaker
- Mounting feet, handle lock and terminal covers available separately
Photos show a 1-pole DIN-rail miniature breaker. A molded-case breaker photograph is not yet in this listing. A DC miniature-breaker family is omitted until a data sheet is on file. 63 A and 70 A are not listed on the 5–60 A DIN-rail family.
Spec sheet: CT-MCB489 / CT-MCCB UL 489 breakers data sheet (PDF). Quote only: request pricing or call (307) 206-0534.
Why Pros Buy Direct from Conversions Tech
Quality-tested and UL Listed. Every product we carry is built to our specifications by certified manufacturing partners and quality-verified before it ships. UL/CSA listed where required, NEC compliant.
Cross-reference savings. Direct equivalents to Burndy, Hubbell, and other OEM part numbers at up to 30% less — same specs, same certifications, without the big-brand markup.
Real technical support. Need a torque spec, die reference, or an OEM quote? You’ll speak directly with the Conversions Tech engineering desk — not a script reader — for instant answers, custom kitting, and private-label options.
Fast US fulfillment. In-stock items ship same day from Oxnard, CA, by ground or expedited.