Reference
NEMA Enclosure Ratings Explained: 1, 3R, 3, 3X, 4, 4X, 6, 12 and 13, IP Equivalents, and Which Rating Each Location Needs
What each NEMA 250 enclosure type protects against, the nearest IP equivalent, why IP and NEMA do not convert exactly, and a location table for disconnects, junction boxes, combiners and controls indoors, outdoors, in washdown and in corrosive sites.
Read more
Cable Jacket Ratings Explained: CMP, CMR, CMG, CM, CMX, LSZH and Direct Burial, Where Each Is Allowed by NEC 800.113 and Article 725
What each communications and low-voltage cable jacket rating means, the flame test behind it, the substitution hierarchy that lets a higher rating replace a lower one, and a room-by-room table of which rating the NEC requires for Cat6, coax, thermostat and speaker cable.
Read more
Neutral Bar and Ground Bar Sizing: Positions, Wire Range and Bonding by Service Size, for Panelboards, Subpanels and Transfer Switches
How to pick an add-on neutral or ground bar: count the terminations, match the wire range to the largest conductor, choose the main lug size from the service, and know when the bar must be bonded to the enclosure and when it must be isolated.
Read more
MC4 Crimp Procedure That Passes the Pull Test: Strip Length, Crimp Height, Tool Setting, Assembly and Torque for UL 6703 Solar Connectors
The field procedure for crimping MC4 and MC4 Evo2 connectors on 10 and 12 AWG PV wire so every joint passes a pull test: strip length, contact orientation, ratcheting crimp cycle, the inspection window, gland torque, and the ten faults inspectors and O&M crews find most.
Read more
Conduit Fill Chart: Maximum THHN/THWN Conductors in EMT, Rigid and PVC by Trade Size, NEC Chapter 9 Tables 1, 4 and 5
How many THHN conductors fit in each size of EMT, rigid metal conduit and Schedule 40 PVC at the 40 percent NEC fill limit, the rules for one and two conductors, the nipple exception, and how to calculate fill for mixed sizes.
Read more
Split Bolt vs C-Tap vs Insulated Multi-Tap (Polaris): Which Tap Connector to Use by Conductor, Location and Code
The three ways to tap or splice a feeder without a box full of lugs: split bolts, compression C-taps and insulated multi-taps. What each is listed for, where the NEC allows it, insulation requirements, and a selection table by job.
Read more
Ufer Ground (Concrete-Encased Electrode): NEC 250.52(A)(3) Requirements, Rebar Clamp Selection, Conductor Size and Inspection
What a concrete-encased electrode is, when NEC 250.50 makes it mandatory, the 20 ft rebar or 4 AWG copper requirement, which clamp is listed for the connection, how big the grounding electrode conductor has to be, and what the inspector checks before the pour.
Read more
Lug Torque Chart: UL 486A/B Tightening Torque for Mechanical Lugs, Set Screws, Breaker Terminals and Bolted Connections by Conductor Size
The torque values for mechanical lugs, slotted and hex set screws, breaker and panelboard terminals, and the bolt torque for lug-to-bus connections, from UL 486A/B and NEC 110.14(D), with what over- and under-torque do and how to document it.
Read more
UL 486A, 486B, 486C, 467 and 6703 Explained: Which Listing an Electrical Connector Needs, and What Each One Actually Tests
A plain-language reference to the UL standards on connector markings: what each covers, what the test proves, and which one the NEC requires for lugs, splices, grounding connectors and PV connectors.
Read more
Compression Lug Die Chart: Die Index Numbers and Color Codes by Conductor Size for 12-Ton Crimpers (Burndy, T&B, Greenlee, Conversions Tech)
The complete die index and color code table for copper and aluminum compression lugs on 12-ton hydraulic crimpers, 8 AWG to 1000 kcmil, with the number of crimps per barrel and how to read the marking on the lug.
Read more