Technical Resources
Battery Cable Lug Sizing Guide: Inverter Wattage to Cable Gauge, Crimp vs Solder, and ABYC Rules
How to size battery cable lugs from inverter wattage and cable gauge, bare vs tinned, why ABYC prohibits solder-only connections, torque values by stud size, and the crosses to Quick Cable, Burndy, Panduit, and Del City.
Read more
90°, 45°, and Straight Compression Lugs — When to Bend the Barrel
When to specify a 90° flag lug, a 45° lug, or a straight compression lug: NEC 312.6 bending space, cable bend radius, where each bend is used, and how bent lugs are crimped and torqued.
Read more
DC Power Distribution for 12 V, 24 V and 48 V Systems: Busbars, Fuse Blocks, and the ABYC E-11 Rules
How to size busbars, choose the right fuse family (ATO, MIDI, MEGA, ANL, MRBF, Class T), and wire barrier terminal strips for 12 V, 24 V, and 48 V systems — with the ABYC E-11 rules on terminals per stud and the seven-inch fuse rule.
Read more
Grounding Accessories and the NEC: Bushings, Pigtails, Bonding Jumpers, and Rebar Clamps
Insulated grounding bushings, pigtails and grounding screws, water heater bonding kits, braided jumpers, and rebar clamps — what each one does and the NEC section (250.97, 250.146, 250.148, 250.8, 250.104, 250.98, 250.52) that requires it.
Read more
Split Bolt Cross-Reference Chart: Burndy KS, ILSCO IK, Blackburn H, NSI N-Series
Verified cross-reference chart for copper split bolt connectors: Conversions Tech 610-series to Burndy SERVIT KS, ILSCO IK/IK-N, Blackburn Type H, and NSI N-series, with equal-range, min-tap, and torque.
Read more
Split Bolt Connectors: Sizing, Torque, Taping, and Where the NEC Won’t Let You Use One
How to size, torque, and insulate copper split bolt connectors, what the equal-range and minimum-tap figures mean, and the NEC rules that decide where a split bolt is and is not permitted.
Read more
How to Crimp Irreversible Compression Grounding Connectors (C-Taps, Figure 6, Figure 8)
Step-by-step field procedure for crimping UL 467 irreversible compression grounding connectors: tool and die selection, conductor prep, crimp sequence, and the inspection marks that prove the joint.
Read more
Irreversible Compression Grounding Connectors: Where, How, and Why to Use Them
A working guide to irreversible compression grounding: what the NEC and UL 467 actually require, where compression beats exothermic welding and mechanical clamps, and how C-taps, Figure 6, and Figure 8 connectors are specified.
Read more
LB vs LL vs LR vs T vs C: Conduit Body Types Explained (With Cross-Reference Chart)
What's the difference between LB, LL, LR, T, and C conduit bodies? A contractor's guide to choosing the right type and size, with a Crouse-Hinds, Appleton, and O-Z/Gedney cross-reference chart.
Read more
Starlink RV Installation Guide: Mounts, Roof Entry & 12V Power (2026)
Mount selection, the five-step roof entry that never leaks, DC power without the inverter penalty, and the $130-225 parts list — the complete Starlink RV installation guide.
Read more
Introducing the CT-40 Rack & Enclosure Line: Server Racks, Network Cabinets, and Outdoor Enclosures for the Modern White Space
Conversions Tech launches the CT-40 rack and enclosure platform: 42U-48U server racks, NEBS Zone 4 seismic cabinets, network cabinets with 12 door styles, open frames, wall-mount cabinets, IP55 outdoor enclosures, and charging solutions - all engineered to ANSI/EIA-310 and available with project pricing.
Read more
How to Run Starlink Mini on 12V: The Complete DC Wiring Guide (2026)
Skip the inverter and cut Starlink Mini power draw 30-40%. Fuse sizes, wire gauges, converter options, and a five-step hardwire procedure for RV, truck, marine, and off-grid systems.
Read more